CO-BRA Bond ® The Oxide Alternative |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CO-BRA Bond ®Product DescriptionThe CO-BRA BOND® Process is a modified peroxide/sulfuric acid process designed to prepare copper surfaces prior to multilayer lamination of printed wiring boards.The CO-BRA BOND® solution promotes the formation of a brown copper-organic coating, which enhances the surface for resin bonding. This structure improves bond strength over conventional oxide coatings, especially on high Tg, high performance materials. The CO-BRA BOND® process is a much shorter process than a standard oxide process and operates at a lower temperature. Solution makupCO-BRA BOND® Predip:
CO-BRA BOND®:
Operating condiitions
Recommended process cycle
Bath operation and maintenanceThe CO-BRA BOND® Process is controlled similar to other peroxide/sulfuric etchants. CO-BRA BOND® Oxidizer (peroxide), sulfuric acid and copper are monitored and controlled via simple titration.CO-BRA BOND® Oxidizer, CO-BRA BOND® Replenisher A, CO-BRA BOND® Replenisher B and sulfuric acid are consumed in proportion to the amount of copper removed. For etching 1 surface square foot of laminate (50% copper surface area) the amount consumed will be:
As work is processed the copper concentration will continue to increase. The copper level should be kept below 20 g/L to provide consistent etch rate. The amount of copper etched should be monitored on a regular basis using cleaned copper clad laminate. The amount etched can be calculated as follows: Amount etched (µin) = weight loss (g)/(0.0212 x surface area (sq. ft.)) Amount etched (µ) = amount etched (µin)/39.4 The etch rate is affected by the CO-BRA BOND® Oxidizer concentration as shown in Graph 1. Sulphuric Acid specificationsSulfuric acid used with the Electrochemicals CO-BRA BOND® process should be electrolytic grade.
Contaminants should not exceed the below listed maximums:
EquipmentTanks, tank linings, pumps, and other handling equipment should be suitable for use with 8% v/v sulfuric acid and 2 - 4% v/v hydrogen peroxide.Most 300 Series Stainless Steel equipment may be used to handle the CO-BRA BOND® solution, provided the bath contains a minimum 3.85 g/l of metallic copper (15 g/l CuSO4 5H2O). Passivation of newly welded stainless steel equipment with nitric acid is recommended. The mixing procedure outlined in this bulletin is recommended to minimize attack on stainless steel. Tanks Reinforced fiberglass (oxidation resistant resin), polyethylene, polypropylene, stainless steel (300 Series), etc. Pumps (Circulation and Transfer) Stainless Steel (300 Series), PVC (unplasticized), etc. The supplier should approve magnetic-driven plastic pumps. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||